Circular Chart Recorder
– CR6″ No Display
CR2010 series of circular chart recorders are available in 3 different sizes of the charts i.e. 4”, 6” and 11”. If you want better readability in small space, this 6” chart recorder is a perfect fit. These recorders are widely used in low temperature equipment, blood banks, incubators and any more places. It takes direct inputs from RTD Pt-100 / process inputs like 4-20mA. Standard chart speed available are 4Hr/ Rev; 24 Hr/ Rev and 168 Hr / Rev (7Days/ Rev). These recorders are microcontroller based. Crystal controlled chart drive ensures accurate chart speed. Stepper motors for both pen and chart drive, ensures no lag and no backlash. With a cutout of 200 x170 mm and smallest depth, makes it very convenient to use. Transparent polycarbonate door makes the chart visible from distance. They come with universal power supply as a standard feature. Other power supply inputs are also available.
Features
- 6” Chart Width
- Single Analog Input channel
- Direct Input Standard Pt-100 sensors
- Process Input through 4-20mA
- No Display
- Universal Power Supply 85-264 V AC, 47-63 Hz
- Other power supply inputs on request
- Battery Back up
- 4/ 24 / 168 Hrs / Rev of chart Speed
- Customized chart speed
Specification
Model No | CR2010 Series; 6″ Recorder |
Product Code* | 20×00 |
Recording System | |
Pens | |
No. of Pens | 1 |
Pen Marking | Continuous |
Pen Response Time | < 5 Sec (Full Scale) |
Pen Resolution | Stepper Motor Controlled, better than 0.1% FSD |
Overshoot | None |
Chart | |
Chart Speed | 7 days/rev; 24Hr/Rev and 4H/Rev |
Chart Calibrated Radius | 2.3″ (approx. 59mm) |
Chart Ranges | Standard (Refer Table 2) / Customized (Please specify) |
Display, Operator Panels, and Input | |
Display Type | None |
Status Indicator | LED |
Panel Keys | Front panel KB consisting of 2 keys for programming and calibration |
Analog Input | RTD PT-100 / 4-20 mA (External shunt resistance of 50 Ohm ±0.1%) |
Sensor Type and Range | Refer to Table 1 |
Scan Rate | Continuous, 1 reading per second |
Protection | |
RTD Input Impedance | > 20 MΩ |
Volt Input | N/A |
mA Input | 50Ω / 2.7Ω Shunt External |
CMRR | > 100 dB @ 50, 60 Hz at 3 Samples per Second |
NMRR | > 50 dB @ 50, 60 Hz at 3 Samples per Second |
Maximum Common Mode Voltage | 5V AC |
Environmental | |
Temperature (Operation) | 5˚C to 45˚C |
Temperature (Limiting) | 0˚C to 50˚C |
Temperature (Storage) | -20˚C to 60˚C |
Humidity (Operation) | 10% to 80% RH (Non-Condensing) |
Humidity (Storage) | 5% to 90% RH (Non-Condensing) |
Altitude | < 2000 meters |
Table 1: Sensor Type, Range, Accuracy and Max Error Specification
Input Type | Valid Input Range | Resolution Chart | Accuracy | Linearization Error (Max) |
---|---|---|---|---|
PT-100 (RTD) | -200 to +850˚C | 2% | +/- 0.5% FSD | ±0.7˚C Max |
mA | 4-20 mA | 2% | +/- 0.5% FSD | ± 0.1% Max |
Table 2: Standard Available Chart Ranges
Sr. No. | Range** | Speed | Size | Part No. | Part Description |
---|---|---|---|---|---|
21 | 0 to 100 | 24H | 6” | 304001 | D60100 |
22 | 0 to 150 | 24H | 6” | 304002 | D60150 |
23 | 0 to 200 | 24H | 6” | 304005 | D60200 |
24 | 0 to 300 | 24H | 6” | 304007 | D60300 |
25 | -50 to +50 | 7 Day | 6” | 305005 | W6-50+50 |
26 | -100 to +100 | 24H | 6” | 306005 | D6-100+100 |
27 | -200 to +200 | 7 Day | 6” | 307005 | W6-200+200 |
28 | -50 to +150 | 24H | 6” | 308005 | D6-50+150 |
29 | 0 to 100 | 7 Day | 6” | 309005 | W6-0+100 |
30 | -75 to +75 | 24H | 6” | 310005 | D6-75+75 |
31 | -100 to +50 | 7 Day | 6” | 307005 | W6-100+50 |
32 | +50 to -100 | 7 Day | 6” | 307008 | W650-100 |
33 | +40 to -10 | 7 Day | 6” | 307007 | W640-10 |
34 | 0 to +50 | 7 Day | 6” | 307004 | W6050 |
35 | 0 to 10 | 7D | 6” | 307012 | W6010 |
36 | +20 to -10 (PS) | 7D | 6” | 308009 | W620-10PS |
37 | +50 to -100 (PS) | 7D | 6” | 308008 | W650-100PS |
38 | -50 to +50 (PS) | 7D | 6” | 308005 | W6-5050PS |
39 | +40 to -10 (PS) | 7D | 6” | 308003 | W640-10PS |
40 | -50 to +50 (PS) | 7D | 6” | 210042 | W6-5050PS |
50 | Other Please Specify |
** First value in the chart is at the center of the Chart.
# PS: Pressure Sensitive Chart
Specification listed are for each of the modules that can be fitted. Refer to the order code for the exact modules fitted in your system. Specifications for the modules that are not fitted, will not be applicable.
Accessories
1) Charts: 100Nos.
2) Panel Mounting Clamps: 2 Nos.; Part No. – 210034
3) Pen: 5 Nos. (Red Pen); Part No. – 217006