GSMAlert for Scanners
GSM Alert system from G-Tek is a versatile alert system to inform about the event through SMS and voice over GSM network. It can take up to 15 potential free inputs and on alert can inform up to 20 nos.
GSM alert system can be easily integrated to your existing system if you have one potential free contact. Since GSM Alert System has, a common to all relay output, the buzzer or hooter connected to your existing system can be transferred here for seamless performance.
Configuration of Alerts, Message for alert, recording of voice, priority of alerts all are fully programmable using USB interface. It has a built-in memory to store the time of occurrence of the alert, when the SMS/Voice was send and to whom it was successful / not successful.
The memory is a rollover type and it can store up to last 1500 events. Standard / 21CFR Part II compliant GSM ViewLogTM is a perfect companion for statutory compliance.
Features
- Signal strength checking
- Up to 20 contact numbers
- Up to 15 alert messages and 4 different voice calls
- Settable Alert priority
- Field programmable message strings and voice recording
- Alert log details
- Remote Arming, Disarming and Partial Disarming
- External Battery Backup
- Rollover memory
- Relay output for connecting to hooter
- LED status indicators
Specification
Model No | GSM Alert System |
Product Code | 7xxxxxx |
Input | |
No of Alert inputs | 5 / 10 /15 |
Type of input | Potential free contact |
Voice and Messaging | |
Mobile System | GSM |
No of Mobile Phones where SMS / Voice messages can be send | 5/ 10/ 15/ 20 |
Setting of Mobile Nos | User Configurable |
Alert messages | User Configurable |
SMS Alerts | Each Maximum of 135 characters long |
Voice Recording | Through Built-in Microphone |
No of Voice Messages | 1/ 2/ 3/ 4 |
Arming / Disarming / Partial Arming | Through SMS |
Display and Operator Panels | |
Display Type | LED for status and Error |
Status Indicator | Status –
Network – Healthy / Failure Health – Device health |
Panel Keys | Two Keys to Test the System and Reset the Alarm condition |
Environmental | |
Temperature | (Operation)5˚C to 45˚C |
(Limiting) 0˚C to 50˚C | |
(Storage)-20˚C to 60˚C | |
Humidity | (Operation) 10 to 80 % RH Non Condensing |
(Storage) 5 to 90 % RH Non Condensing | |
Altitude | <2000 meter |
Power Requirement | |
Supply Voltage (Mains Operated through adapter) | 85-265VAC 47-63Hz |
Battery backup | Yes |
DC Adapter Operated | Yes |
Power | 12W Max With Maximum Configuration |
Fuse Type | None |
USB | |
Communication | USB 2.0 |
Protocol | Proprietary |
Battery Backup | |
Battery | 4×1.5V AA Ni-MH rechargeable battery |
Battery Charger | Yes; Built–in with Overcharge, Over temperature; Over discharge protected |
Battery Reverse Polarity | Protected |
Minimum Back up | 18 Hrs. |
General | |
Termination | Non Interchangeable , Removable Plugs, Individual For Each Input |
Data Storage | Non Volatile Flash Memory For Parameter and data Storage |
No of Data Storage | Last 512 / 1024 / 1536 records of error logs |
Safety | |
Safety | IEC 61010-1 |
Pollution Degree | II |
Installation Category | II |
Vibration | NA |
Shock | NA |
Relay Output Details | |
No of Relay Output | 1 |
Output Type | 1 Form C |
Life expectancy | Mechanical:10^7 operations |
Electrical: 10^5 operations | |
Load | 1A, 230VAC resistive |
Relay refresh rate | Common to all; On occurrence of Alert and remains ON until reset |
Isolation Relay – Relay | 2.5 KV 1 Minute |
Isolation Relay Contact – GND | 1.5 KV 1 Minute |
Overall Dimension | |
Dimension L x W x D (mm) | 200x90x35 |
*Features depends on the options ordered; Specifications are subject to change without notice
Accessories
1. 15 V DC 1.2Amp Adapter
Part No.: 200661
2. Ethernet Cable
Part No.: 236249
3. USB Cable
Part No.: 210027
4. GSM Rubber Duck 5 dB Antenna; Frequency Range: 800-1900 MHz
Part No.: 200477